Hematologia

AL 808 Roche

OLYMPUS DIGITAL CAMERAMODEL    
Autolyzer AL 808
COUNTS/DILUTION (APERTURE)    2/2
POWER REQUIRED, VAC    90-240. 50/60 Hz
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY)    34x 45 x 43 (13.4x 17.7 x 16.9)
WEIGHT, kg (lb) (DISPLAY)    19.5(43)
Usa (Number installed)    
TECHNIQUE    Volumetric impedance
TESTING PACE    60
INTERFACE PROTOCOL (REPORT DISPLAY)    1parallel, 2 RS232

 

 

 

 



ABBOTT CELL DYN 1300

Cell-Dyn1300

 

 

 

 

 

 

 

 

 

 



ABBOTT CELL DYN 1600

celldyn1600The Abbott Cell Dyn 1600 is an automated cell counter that has many capabilities. Multiple automatic programs eliminate most time consuming procedures associated with cell counting. The Abbott Cell Dyn 1600 accepts samples from open tubes only and will run the following parameters: WBC MCHC LYM% LYM# RBC PLT HCT HGB RDW MCH MID% MID# MPV MCV GRAN percentage GRAN number as well as histograms for WBC RBC and PLT.

The Abbot Cell Dyn 1600 streamlines many of the tedious procedures associated with cell counting. It has a throughput of 60 samples per hour.

Abbot Cell Dyne features include; advanced data management and measurement capabilities volumetric metering automatic probe wipe and rinse electronic resistance automatic startup and shutdown automatic cleaning modes automatic detergent rinse between cycles various data output options and automatic multi-point calibration.

 

 



ABBOTT CELL DYN 1700

SAM_2823
 Cell-Dyn 1700 – 3 Diff. Hematology Analyzer

Specification
Manufactures:         Abbott
Method:        Impedance technology
Parameters:     WBC, RBC, HGB, PLT, LYM, %LYM, GRAN, %GRAN, MID, %MID, MCV, HCT, MCH, MCHC, RDW, MPV, PCT, PDW
Aspiration volume:    Only 30 µL
Throughput:        60 samples/hour
Memory:        for 10,000 cycles with graphics

The CELL-DYN 1700 is 3-part differential analyzer offering 18 parameters and extensive QC and data management capabilities. Applications of the CELL-DYN 1700 analyzer include two-dimensional laser platelet and red cell analysis, 3-D MCV measurement ensures accurate RBC analysis, Single-step dilution reticulocyte procedure, and five-part leukocyte differential.

 

 

 



ABBOTT CELL DYN 1800

CellDyn1800_23081AY.1 Cell-Dyn 1800 – 3 Diff. Hematology Analyzer

Specification
Manufactures:         Abbott
Method:        Impedance technology
Parameters:         16 parameters
Aspiration volume:    Only 30 µL
Throughput:        60 samples/hour
Memory:        for 10,000 cycles with graphics

The CELL-DYN 1800 is 3-part differential analyzer offering 16 parameters and extensive QC and data management capabilities, the CELL-DYN 1800 meets the needs to today’s growing labs. The CELL-DYN 1800 is fits in standard physicians laboratories. The system utilizes impedance resistance to measure human cells while incorporating the patented von Behrens plate to reduce coincidence counts from each sample. The CELL-DYN 1800 use only three reagents, including CN-Free lyse that are individually packaged and monitored to eliminate waste and improve operator safety. 

 



ABBOTT CELL DYN 3000

celldyn3000Cell-Dyn 3000 – 5 Diff. Hematology Analyzer

Specification
Manufactures:     Abbott
Method:    Impedance technology
Parameters:     22 Parameters: WBC, RBC, Hgb, Hct, MCV, MCH, MCHC, PLT, MPV, RDW,
M%, M#, G%, G#, E%, E#, L%, L#, B%, and B#
Throughput:    110 CBC samples/hour
Memory:    for 10,000 cycles with graphics
The CELL-DYN 3000 is a multi-parameter automated hematology analyzer designed for in vitro diagnostic use in clinical laboratories. This analyzer has standard features such as closed tube sampling, RS 232 Interface, hydrodynamic focusing Leukoprotective reagent, 5 part differential, histograms and scatterplots. WBC Scattergrams, RBC & PLT Histograms are presented on screen and printed on included graphic printer. Full PC-compatible computer system with QC, Control Values, Reagent logs, Levy-Jennings charts, Westguard rules, etc.



ABBOTT CELL DYN 3200SL i CS

CellDyn3200SL_59889AF.1Cell-Dyn 3200 – 5 Diff. Hematology Analyzer

Specification
Manufactures:     Abbott
Method:    Impedance technology
Parameters:     23 parameters + reticulocyte
Throughput:    71 samples/hour
Memory:    for 10,000 cycles with graphics

The CELL-DYN 3200 is a multi-parameter automated hematology analyzer designed for in CellDyn 3200CS_30650AH.1vitro diagnostic use in clinical laboratories. The analyzer uses optical light scatter for WBC, RBC, PLT and Reticulocyte analysis to meet the needs of today’s medium volume laboratories. The instrument offers simple operation, accurate 5 part WBC differential analysis, automated sample handling and reliability. The system combines MAPSS (Multi-Angle, Polarized Scatter Separation) technology with flow cytometry to achieve a high level of accuracy and precision.Data storage for 10,000 cycles with graphics for easy review of patient results. Only 3 reagents are needed for complete CBC with 5 part differential analysis.

 



ABBOTT CELL DYN 3500SL
celdyn3500

Cell-Dyn 3500 – 5 Diff. Hematology Analyzer

Specification
Manufactures:     Abbott Diagnostics
Method:    White Blood Cells – simultaneous optical and impedance technology
        Red Blood Cell and Platelet – impedance technology
Parameters:     WBC, NEU#, NEU%, LYM#, LYM%, MONO#, MONO%, EOS#, EOS%, BASO#, ASO%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, MPV
Throughput:    90 samples/hour
Memory:    for 10,000 cycles with graphics

Cell-Dyn 3500 automatically performs a shut-down cycle and places itself in a standby mode. It offers both open and closed sampling options on two instrument versions. 

 

 

 



ABBOTT CELL DYN 3700SL i CS

OLYMPUS DIGITAL CAMERACell-Dyn 3700 – 5 Diff. Hematology Analyzer

Specification
Manufactures:     Abbott
Method:    White Blood Cells – simultaneous optical and impedance technology
Red Blood Cell and Platelet – impedance technology
Parameters:     23 parameters + reticulocyte
Throughput:    90 samples/hour
Memory:    for 10,000 cycles with graphics

Cell-Dyn 3700 is a multi-parameter, automated hematology analyzer designed for in vitro diagnostic use in clinical laboratories. It offers advanced diagnostic capability for medium to high volume clinical laboratories.
Cell-Dyn 3700 use only 4 for complete CBC with 5 part differential analysis.
Semi-automated Reticulocyte analysis based upon NCCLS/ICSH methods reduces time spent performing manual retic counts.

 

 



Abbott Cell Dyn Ruby

CellDyn Ruby_34302BG.1

CELL-DYN Ruby – jest najnowszym produktem oferty hematologicznej, ten w pełni funkcjonalny system oparty jest o opatentowaną technologię optyczną o nazwie MAPSS, stając się standardem dla laboratoriów, pozwalającym na uzyskaniu największej ilości właściwych wyników uzyskanych w pierwszym pomiarze oraz zmniejszeniu wskaźnika analiz manualnych, a także wyznaczającym kierunek wprowadzania zaawansowanego i w pełni intuicyjnego oprogramowania.

 Cell-Dyn Ruby – 5 Diff. Hematology Analyzer

Specification
Manufactures:     Abbott
Method:    WBC AND DIFFERENTIAL 4 angle optical MAPSS™ Multiple Scatterplot Analysis
PLATELETS Dual angle optical analysis, no extra reagent, no reflex testing requirement
RETICULOCYTES New Methylene Blue NCCLS method, supravital staining technique
Parameters:     23 parameters + reticulocyte
Throughput:    up to 84 samples/hour
Memory:    for 10,000 results with graphics

Cell-Dyn Ruby is a multi-parameter, automated hematology analyzer designed for in vitro diagnostic use in clinical laboratories. It offers advanced diagnostic capability for medium to high volume clinical laboratories. 

 



ABBOTT CELL-DYN EMERALD

CellDyn_Emarald_030411-002076.2Wymiary i waga:

– Wysokość: 35 cm
– Szerokość: 25 cm
– Głębokość: 35 cm
– Waga: 9 kg (bez odczynników)

Wydajność:

– Do 60 próbek/godz

Kontrola jakości:

– 6 zbiorów kontrolnych
– 100 rezultatów w zbiorze
– wykresy Levey-Jenningsa
– wczytywanie/zczytywanie plików kontroli
– program eQC

Zarządzanie danymi:

– Funkcja wyszukiwania: ID/Data
– Flagowanie wyników patologicznych
– 1.500 wyników z histogramami
– 60.000 wyników na zewnętrznym nośniku USB
– Programowalne wartości referencyjne
– Programowalne jednostki
– Czytnik kodów paskowych: Code 128, 39, interleaved 2 z 5

Nowoczesny:
– Ekran dotykowy
– Wyjście USB
– Password – 4 poziomy dostępu
– Automatyzacja procedur

Cell-Dyn Emerald – 3 Diff. Hematology Analyzer

Specification
Manufactures:     Abbott
Method:    Impedance counting
Parameters:    WBC, RBC, Hb, Hct, MCV, MCH, MCHC, PLT, lymph %&#, gran %&#, mid %&#, RDW, MPV
Throughput:    up to 60 samples/hour
Memory:    for 1500 results

The CELL-DYN Emerald functions as a compact, automated hematology analyzer, which has been designed for the purpose of in-vitro diagnostics in clinical labs. The Emerald is highly reliable, simple to use, and easily controllable. The Emerald’s software can be controlled by a touch screen, which comes with an in-built keyboard.



ABBOTT CELL DYN Sapphire

OLYMPUS DIGITAL CAMERACell-Dyn Sapphire – 5 Diff. Hematology Analyzer

Specification

Manufactures:   Abbott

Method:            MAPSS technology plus 3 color fluorescence

Parameters:      23 parameters + reticulocyte

Memory:           for 10,000 cycles with graphics

 Cell-Dyn Sapphire is solution for high volume hematology laboratories. It is a multi-parameter automated hematology analyzer designed for in vitro diagnostic use in counting and characterizing blood cells. The analyzer features MAPSS technology plus 3 color fluorescence to provide our most comprehensive testing capability.

WBC and differential: Identification and enumeration of WBCs and subpopulations, identification of abnormal cell types, identification of NRBCs, identification of platelet clumps.

Nucleated Red Blood Cell (NRBC) Enumeration – Using red fluorescence, every sample is analyzed for the presence of Nucleated Red Blood Cells with no need to reflex to a different test mode. During sample analysis, NRBCs are enumerated as a unique nucleated cell sub-population.

The Platelet count is considered one of the most clinically important CBC parameters. The instrument uses multiple technologies to provide the highest degree of accuracy for this critical result.

Reticulocyte analysis – The instrument uses fluorescent flow cytometry to provide automated, random access reticulocyte analysis.



ABX Pentra 60

Pentra60_405P604607.1

Specyfikacja techniczna

    Waga: 35 kg
    Zasilanie: 100/240 V – 50/60 Hz – 200VA
    Wymiary:
        wysokość – 51,6 cm
        szerokość – 44,4 cm
        głębokość – 48,1 cm
    Drukarka: laserowa
    Wydajność: 60 oznaczeń/godz.
    Parametry komputera: mikroprocesor 68 331, RS 232C,
    komunikacja jedno i dwu– kierunkowa
    Pojemność wyników: ostatni wynik

26 parametrów krwi obwodowej
CBC / 5-częściowy DIFF
Unikalne możliwości

    Otwarty system pobierania
    Minimalna ilość krwi do analizy (CBC – 30 µl, DIFF – 53 µl)
    Efektywny i ekonomiczny analizator hematologiczny
    Technologia DHSS *
    Technologia MDSS *

Overview
Highly compact and cost-effective.
Micro-sampling from whole blood (CBC : 30 µL – DIFF: 53 µL)
Cytochemistry, Impedance (real cell volume measurement) & Optical (analysis of the internal cellular structure by measuring light absorbance) – DHSS* Technology.
Perfect homogenization of blood samples with reagents – MDSS** Technology.

Features

Throughput: Up to 60 samples/hour
Reagents: Only 4 onboard reagents and 1 diluent
Perfect differentiation of the 5 WBC sub-populations with DHSS* Technology
3 histograms for RBC, BAS/WBC and PLT together with the 5 DIFF Matrix.
Basophils counted through specific channel
High resolution matrix includes the determination of 2 additional subpopulations (% and #): Atypical

Lymphocytes (ALY***) and Large Immature Cells (LIC***)     

* DHSS : Double Hydrodynamic Sequential System (HORIBA Medical Patent)

** MDSS : Multi-Distribution Sampling System (HORIBA Medical Patent)

*** RUO parameters (Research Use Only)


BD Sedi 15

BD Sedi 15_SA08304379.1

 

 

 

 

 

 

 

 

 

 

 

 

 


BAYER ADVIA 120

Advia120_IR26420138.1

OPIS I SPECYFIKACJA TECHNICZNA :

  • najnowocześniejsze i wiarygodne techniki pomiarowe (Cytometria przepływowa i pomiar laserowy).
  • Unikalny pomiar hemoglobiny komórkowej.
  • Dwuwymiarowa analiza PLT : MPC jako wskaźnik aktywacji płytek.
  • Dwutorowy pomiar leukocytów (lampa halogenowa, dioda laserowa).
  • Wysoka czułość flag (NRBC, Atyp Lymph, Blasts, ImmGran, RBC Fragm, PLT Clumps).
  • Wydajność analizatora na godzinę: 120 oznaczeń CBC + 5-DIFF lub 74 oznaczeń CBC + 5-DIFF + RET.
  • 3 sposoby podawania próbki – ręczny z otwartej probówki, ręczny z zamkniętej probówki, automatyczny z podajnika.
  • podajnik automatyczny na 150 probówek (15 raków po 10 probówek) z wewnętrznym czytnikiem kodów kreskowych.
  • 64 definiowalne przez użytkownika zakresy norm dla płci i wieku



BAYER ADVIA 60 CS

ADVIA60.1

ADVIA 60 CS – 3 diff hematology analyzer

Specification
Manufactures: Bayer/Siemens
Method: Volume Impedance
Sample: 10 l
Parameters: 18
Throughput: 60 samples/hour
CS: Closed System

Hematology analyzer ADVIA 60 is designed for analytical laboratories in hospitals and clinics and also for analytical laboratories working independently. 

 Highlights
♦ Original Instrumentation provided by Siemens Healthcare Diagnostics.
♦ Total number of assays tested: 16.
♦ Diamond Down-To-Frame® refurbishment provided.
♦ Refurbishment includes disassembly and total restoration.
♦ Process continues with assembly, repair, and diagnostics.
♦ Certification concludes with calibration, QC and QA validation.
♦ Contact Diamond for pricing, specifications and availability. 



Beckman Coulter LH500

SAM_2917

LH500 – Hematology Analyzer

Specification
Manufactures:         Beckman Coulter
Method:        Volume Impedance
Parameters:         28: 5-pt Differential
System:         Open system
Throughput:        105 samples/hour

Hematology Analyzer LH 500 helps increase productivity, enhances linearity, improves diff flagging and reduces false positive flagging – all in a compact design that fits your needs and your limited lab space.It offers advanced VCS technology, providing the greatest sensitivity, specificity and efficiency in white cell differential analysis. 

 

 



Beckman Coulter LH750

SAM_2792

LH750 – Hematology Analyzer

Specification
Manufactures:         Beckman Coulter
Method:        Volume Impedance
Parameters:         28: 5-pt Differential
System:         Open system
Throughput:        105 samples/hour

Hematology Analyzer LH 750 is equipped with superior technologies, NRBC enumeration and random access capabilities. These advancements help high-volume labs eliminate manual pre-sorting of samples and speed results to clinicians. With this system, you can improve overall efficiency, while maintaining the highest degree of testing accuracy.


BECKMAN COULTERT-540

OLYMPUS DIGITAL CAMERA
Beckman/Coulter T540 is a quantitative and automated hematology analyzer, which is designed for in vitro diagnostic use in clinical laboratories. Beckman/Coulter T540 is capable of measuring the following parameters such as WBC, RBC, Hgb, Hct, Plt, L%, and L#. Using a sample volume of 100 uL, you can measure 40 CBCs per hour.
T540
[-] Hide Specifications
Attributes
Depth     20 in
Height     20 in
Width     25 in
Weight     90 lbs

 



BECKMAN COULTERT-660

OLYMPUS DIGITAL CAMERA

T660 – Hematology Analyzer

Specification
Manufactures: Beckman Coulter
Method: Coulter Principle counting and sizing
Parameters: 6 parameters
sample Volume: 100 l
Throughput: 60 samples/hour

Hematology Analyzer T 660 is a compact, fully automated, blood cell counter which measures WBC, RBC, Hb, haematocrit, MCV and platelet count on a 100 microliter sample of whole blood.

 



BECKMAN COULTER T890

OLYMPUS DIGITAL CAMERA

 T890 – Hematology Analyzer

Specification
Manufactures: Beckman Coulter
Method: Coulter Principle counting and sizing
Parameters: 8 parameters
sample Volume: 100 l
Throughput:  60 samples/hour

Hematology Analyzer T890 – is system designed for small laboratories that carry out up to 50 CBCs per day.

 

 



Mindray BC 3000 Plus

BC3000Plus_RJ-94103171.2
BC-3000Plus is an analyzer for the mainstream laboratory that prioritizes quality results. Equipped with a large, color LCD Display, built-in thermal printer and huge storage capacity, our user-friendly hematology analyzer brings the convenience and accuracy of the reference laboratory right into your practice, offering maximum value with low running costs.

. Three-part differentiation of WBC, 19 parameters +3 histograms
. Two counting modes: whole blood and prediluted
. Throughput: 60 samples per hour
. Micro sampling of 13 ul
. Automatic diluting, lyzing, mixing, rinsing and unclogging
. Storage for up to 35,000 sample results (including histograms)
. Large Color LCD Display

 

 

 



Beckman/Coulter AcT 5 diff
AcT 5 Diff_AE52175.1

Beckman Coulter AcT 5 Diff Hematology Analyzer Overview

The COULTER AcT 5diff CP (Cap Pierce) hematology analyzer is another member of the growing Ac T 5 diff family. Not only does the AcT 5diff CP system offer 5-part differential testing for the most complete results it improves operator safety by featuring state-of-the-art cap piercing technology for closed tube sampling.

In Addition the COULTER AcT 5diff CP (Cap Pierce) hematology analyzer is remarkably cost effective. Laboratories that have previously relied on 2-part 3-part or manual differential analyses can move up to efficient 5-part differential hematology diagnostics at an affordable price.

To deliver a 5-part differential analyses the Act 5diff CP system employs Absorbance cytochemistry and Volume (AcV) technology. Monocyte neutrophil and eosinophil populations are identified using the absorbance patterns produced by differential cytochemical staining of their granules versus volume. Lymphocytes remain unstained and the basophil population is analyzed on a separate channel using volume gating and selective lysis.

Easy-to-Use Safe Solution
Cap piercing allows quick and direct access to a closed sample tube – a feature that not only reduces sample handling and saves time but enhances safety. Automated cap piercing also:

    Eliminates operators’ exposure to biohazards
    Increases overall lab efficiency
    Reduces manual processing time

Easy to Operate

    CBC or CBC Diff mode and patient range selectable from the run screen
    One step start-up operation and shutdown
    Accommodates multiple tube sizes for increased system flexibility
    Specially formulated reagents controls and calibrators for accurate results
    Zero daily maintenance

Easy-to-Use Date Management

    Automated quality control evaluation reduces manual errors
    Patient storage streamlines data recall
    Automatic calibration saves time
    Interlaboratory Quality Assurance Program (IQAP) complements your lab’s in-house quality control efforts and increases confidence in your results
    Qualitiative flagging for quicker review of patient results decreases turnaround time
    Twenty user-definable patient and action ranges increases flexibility

Easy On Your Budget

    Affordable 5-part differential technology
    Efficient use of samples and reagents in CBC and CBC Diff modes
    Compact design with on-board reagents requires minimal bench space
    Automated features translate into lower operational costs
    Optimal balance between clinical utility and cost-effectiveness



Beckman/Coulter AcT diff 2

Zdjęcie0115Beckman Coulter AcT Diff II Hematology Analyzer

    Closed vial sampling
    Small 18 uL sample size
    User-definable high/low flagging of patient results and quality control
    Automated quality assurance functions
    Closed vial sampling for controls and calibrators

The Beckman Coulter AcT Diff II Hematology Analyzer delivers performance value and safety for physician office labs and smaller laboratories. It’s an affordable easy-to-use system that offers a small sample volume in both open and closed analysis modes a wide operating range and multiple output formats.

The Beckman Coulter AcT Diff II Hematology Analyzer offers a full range of features to optimize your lab’s efficiency including:

Closed vial sampling that accommodates a variety of collection of tube sizes
Small 18 uL sample size in either closed or open vial modes
User-definable high/low flagging of patient results and quality control simplifies data interpretation
Automated quality assurance functions improve productivity
Closed vial sampling for controls and calibrators provides operator safety
Compact benchtop design requires only two square feet of counter space
Zero routine maintenance and high system reliability help contain costs



Beckman/Coulter AcT 5 diff AL

AcT 5 diff 2 AL
The Coulter AcT 5-part differential (5 diff) autoloader (AL) hematology analyzer from Beckman Coulter (Fullerton, CA, USA) was evaluated at the Florida Medical Center in Fort Lauderdale, Florida, an acute care hospital facility. The AcT 5 diff AL is a new, fully automated bench-top 5-part differential hematology analyzer with automatic loading and sampling. It is designed as a front-line instrument for small- to medium-sized laboratories or as a backup in larger laboratories. We evaluated the performance of the AcT 5 diff AL for complete blood counts (CBCs). The Coulter Onyx AL was used as the reference instrument and the 5-part differential against the reference 400-cell manual differential count (2 operators x 200 cells). A total of 140 patient samples were analyzed in the study, with most of the samples obtained from our own laboratory workload. We supplemented this dataset with pediatric and oncology samples from nearby practices. All samples were analyzed within 4 hours of collection, and the AcT 5 diff AL demonstrated excellent accuracy with correlation values (r) > 0.98 for all directly measured CBC parameters (white blood cell count, red blood cell count, hemoglobin, mean corpuscular volume, and platelets). Reproducibility studies on the AcT 5 diff AL also showed excellent results, with coefficients of variation much lower than the manufacturer’s specifications. Initial differential comparisons showed good correlations for neutrophils, lymphocytes, and eosinophils (r = 0.84, 0.96, and 0.88, respectively) with a lower correlation for monocytes (r = 0.43). On subsequent review and data analysis we found differential discrepancies in 39 of the 140 samples, for which all showed multiple morphological flags, R diff flags, or poor scatterplot separations indicating that the AcT 5 diff AL differential was likely to be inaccurate and that a morphological assessment and differential was necessary. Given the acutecare setting that our laboratory serves and the skewing of the dataset of our study because of the addition of abnormal pediatric and oncology cases, these abnormal sample results were not surprising. These 39 samples all had markedly abnormal differentials with either increased numbers of immature and/or abnormal cells due to such conditions as end-stage liver disease, respiratory failure, renal failure, sepsis and pneumonia, high white blood cell leukemias, and a variety of other acute illnesses. Reanalysis of the differential data, excluding these 39 grossly abnormal samples with R flags and multiple flags, showed the AcT 5 diff AL differential gave very good correlations for neutrophils, lymphocytes, monocytes, and eosinophils (r = 0.93, 0.97, 0.66, and 0.85, respectively). Our technologists were also impressed with the reliability of the AcT 5 diff AL, its ease of use and transfer from stand-by to ready mode, the user friendliness of the software, and the clarity of the printed report. We concluded that the AcT 5 diff AL gives accurate and precise CBC and 5-part differential results and is an excellent, easy-to-use instrument ideally suited for small- to moderate-sized hospital laboratories, as a back-up in a large hospital laboratory, or for use in physician office laboratories.


Beckman/Coulter AcT 5 diff CP

AcT 5 Diff_AE44381.1

The Coulter ACT 5Diff CP supported by Beckman Coulter Inc. is routinely available from Diamond Diagnostics in refurbished condition. All instruments refurbished by Diamond, including the Coulter ACT 5Diff CP, are disassembled down to-the-frame then thoroughly cleaned, polished and eventually refinished with a durable 3 part industrial paint that matches the instrument’s original color and sheen. During re-assembly components are validated, repaired or replaced as needed followed by full diagnostics, calibration and running controls as a final step. Afterward the instruments are inspected and prepared for international transit. Should you wish to receive more information on the Coulter ACT 5Diff CP Hematology Analyzer such as pricing, detailed specifications and availability go to Analyzer Search.
Coulter ACT 5Diff CP
Manufacturer:           Beckman Coulter Inc.
Type           Hematology Analyzer
Parameters:           22: 5-pt Differential
Throughput:           60 samples/hour
Method:           Volume Impedance
Open system:           Open
 W x D x H:           14X14X16 inches / 36X36X41 cm
 Weight:           30 lbs / 14 kilos



Beckman/Coulter AcT 10

Act 10 diff_AD21987.1Beckman Coulter AcT 10 Hematology Analyzer Features

Automated east for all operators
Touch Screen user-friendly interface
Language independent icons
One-step sample processing for fast easy analysis
Automated probe wipe provides safe probe cleaning
Fully automated start-up and shutdown
 No routine maintenance the system is ready when you are
Complete blood count including white cell differential and histograms for WBC RBC and Pit
User definable high/low flagging of patients results
Graphical printout of results including histograms
Choice of six different reporting profiles
Storage of up to 250 patient results
Automated quality assurance functions
Statistical summary of quality control and IQAP data
Automatic sequencing of sample ID number
 Ability to enter institutional header onto reports



DIAGOND-Cell 60
D-Cell 60_RJ-01105276.1

3-part differentiation of WBC with improved cyanide-free reagent system 19 parameters + 3 histograms
Automatic orifice clearing
Automatic sampling probe cleaning
Huge number of sample results, including histograms can be stored
Built-in thermal printer (optional external printer)
Bar code scanner (optional)
Touchpad and normal computer keyboard for convenient data entry
Large color LCD display

Flexible and Easy To Use

    Full blood picture from venous or capillary blood
    Automatic cleaning programs
    Low reagent consumption, cost effective operation
    Low sample volume
    High reliability
    Maintenance free concept

TECHNICAL SPECIFICATIONS
Parameters:
WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH,MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT and Histogram for WBC, RBC,PLT

Principles
Electrical resistance for cell counting
Cyanide free method for hemoglobin



DIAMS 20 3 Diff

SAM_2921PH Diam’s 20
Status:     Open
Item type:     Complete System
Category:     Laboratory
Device:     Hematology Analyzer
Manufacturer:     PH Diagnostics
Model:     DIAMS 20

 

 

 


ERMA PCE-210

Zdjęcie0106

  • prosta obsługa i szybkie pomiary
  • funkcja automatycznego czyszczenia sondy pobierającej
  • wszystkie nastawienia na ekranie dotykowym
  • system automatycznego monitorowania
  • rozsądna cena i obniżka kosztów
  • czas pomiaru 60 próbek na godzinę

 The Erma PCE-210 supported by Erma Inc. is not routinely available from Diamond Diagnostics so please inquire. As you consider purchasing a refurbished instrument from Diamond, rest assured that every instrument that flows through our production facility is disassembled down to-the-frame then thoroughly cleaned, polished and refinished with a durable 3 part industrial paint that matches the instruments original color and sheen. During re-assembly components are validated, repaired or replaced as needed followed by full diagnostics, calibration and running controls as a final step. Afterward the instruments are inspected and prepared for international transit. Should you wish to receive more information on the Erma PCE-210 Hematology Analyzer such as pricing, detailed specifications and availability go to Analyzer Search.
     Erma PCE-210
      Manufacturer:           Erma Inc.
      Type           Hematology Analyzer
            
      Parameters:           15 parameters
            
      Throughput:           60 samples/hour
            
      Method:           Volume Impedence
            
      Open system:           Open
            
      W x D x H:           13X15X18 inches / 33X38X46 cm
      Weight:           43 lbs / 20 kilos



HORIBA ABX PENTRA 120

Zdjęcie0105

  • automatyczny, w pełni zintegrowany system wykonywania i barwienia preparatów
  • do 120 oznaczeń w ciągu godziny
  • jedynie 50 µl pełnej krwi pobieranej do wykonywania preparatu z pierwotnie zamkniętej probówki
  • automatyczne definiowanie kryteriów wykonywania rozmazów mikroskopowych
  • jednowarstwowe rozmazy krwi z dużym obszarem odpowiednim do oceny mikroskopowej
  • automatyczne powtórzenie wyniku patologicznego

 Overview

    Impedance, cytochemistry & focused-flow cytometry (DHSS* technology).
    Walkaway rack loading and continuous feed flexibility.
    Automatic, immediate and user-defined rerun of abnormals.
    48 hours post-draw stability.
    SPS option (automatic slide-maker).

*ABX patent
Features
ABX Pentra 120

    Methods of measurement: Cytochemistry, impedance, absorbance and flow cytometry (Eosinofix* and LMNE matrix)
    DHSS*: Focused flow cytometry and sequential measurement (impedance and absorbance)
    Automatic re-run of samples: Selective and programmable (hematology parameters and smears)
    Rotative mixing of samples: Smooth and efficient
    Liquid valves* ABX (no pinch valves): Reliability and volume accuracy

*ABX patents



HORIBA ABX/ROCHE DIAGNOSTICS MICROS 60

Micros60_73336.2

  • bezpośrednia aspiracja krwi kapilarnej pobranej do kapilaro-probówek
  • możliwość stosowania zarówno systemów zamkniętych jak i probówek klasycznych w wersji CT
  • wydajność: 60 oznaczeń na godzinę
  • korygowanie zjawiska koincydencji: automatyczne
  • kontrolowanie podciśnienia: automatyczne
  • plik kontroli jakości: pełna analiza statystyczna i graficzna
  • plik z wynikami kontroli jakości dla 31 dni i 3 poziomów

 HORIBA ABX Micros 60 Hematology Analyzer

Compact, three-part differential
Eight or 18 parameter
60 Samples/hour (open tubes), 55 samples/hour (closed tubes)
100% „hands-free” open/closed sampling system
Automatic sample probe cleaning and rinsing
No compression, no pinch valves
Variable sized tube holder accepts almost any type of tube, including those used from fingerstick collection devices

The HORIBA ABX Micros 60 is a fully automated hematology analyzer used for in-vitro diagnostics testing of whole blood specimens, platelet PRP samples, and whole blood component concentrates. The HORIBA analyzer uses impedance technology and photometry as measurement methods, as well as stepper motor technology which enables the system to operate without a compressor.

The HORIBA hematology analyzer comes packed with key features such as automatic probe wipe, 8 or 16 parameters including three part differential and histograms, single button operator interface, usage of the MINIPACK combining waste and reagents, smart card based memory storage, and micro sampling of 10µL of whole blood per cycle.

The ability to identify samples, programmable high and low limits for patients, and programmable flag sensitivity are other features which make the ABX Micros 60 analyzera better choice. The HORIBA hematology analyzer can provide sample tests either in closed or open tube modes, allowing a throughput of up to 60 samples per hour.p>

Designed for reliability, less maintenance and noise, as well as increased precision, the HORIBA ABX Micros 60 Hematology Analyzer offers premium performance in every analysis application.

Call us today to learn more about the HORIBA ABX Micros 60 Hematology Analyzer!



Mythic 18/22CT

mythic 22ct mythic18

 

 

 

 

 
The Mythic 18 Vet – The Ultimate Technology in Haematology

The Mythic 18 Vet is a fully automated 18 parameter veterinary haematology analyser. With its compact size and lightweight design, the Mythic 18 Vet is ideal for use as a veterinary specific benchtop analyser in the smallest of veterinary practices or clinics. It is a quick and efficient haematology analyser capable of performing 60 tests per hour and can be used on samples from 10 different species. It requires a low level of maintenance and just a 10μl sample size.
Key Features of the Mythic 18 Vet

    Quick and easy to use
    Fully Automated
    Compact and lightweight
    Colour Touchscreen
    60,000 patient memory*
    Built-in reagent pack
    Multi-language setting (11 languages)
    10 Species Available
    60 second analysis time
    Low power consumption
    Easy maintenance *Expanded from 1,500 with a USB

Mythic 22

22 Parameters + 2 Histograms + 1 Scattergram

WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, PCT, PDW.
LYM % & #, MON % & #, EOS % & #, NEU % & #, BAS % & #.

– Sample volume : 16,7 µl
– Throughput : 50 samples per hour
– Close tube sampling

– Identification :
Alphanumeric ID
Patient ID
Sample ID
Barcode reader (option)

– Only 3 Reagents : Diluent, Only One Lyse & enzymatic Cleaner

– Multilanguage :
English, French, Spanish, German, Italian, Portuguese, Chinese, Cyrillic

– TFT Colour Touch Screen &
Numerical Keyboard

– Flagging : Pathological flags, Lab limits, Reagent alert, Instrument alert

– Logs: System status, Reagents monitoring, Calibration, Q.C., Service

– Datalog:
> 1000 patient’s files in Mythic memory (including demographics & histograms) Extended capacity with external thumb drive.

– External AC 220V / DC 24V power supply

– Mythic 22 AL (autoloader) available soon



Medonic CA 530
Medonic CA530_3635.1

 Medonic CA530 cell analyzer system is a 3-part cell counter

 

 

 

 

 

 

 

 

 


Medonic CA 620

Medonic CA620_2768.1
The CA620 series offers the small to medium-sized laboratory the high quality hematology results normally only achieved with very large hematology systems. Medonic is practically maintenance-free for the end-user. Due to its new QC features, unique flow system, unmatched stability, and outstanding software,the CA620 series performs without compromise. Parameters, 9/16/20. FDA-Cleared. CLIA Classified as Moderately Complex.

General features of the CA620 Series:

    Human, blood bank and veterinary applications available
    Results with hemograms displayed within 60seconds on large graphic screen
    Open tube inlet (125µl) as well as predilute (e.g. 20 or 25µl into 5ml)
    Floating discriminators RBC/PLT, and WBC
    Motor driven cap piercing device as option
    Micro Pipette Adapter as option
    Bar-code reader input as standard for easysample and control identification
    Sample memory for >220 samples with highresolution size distribution curves
    Coincidence correction for all parameters
    HGB turbidity correction on high WBC counts
    Warning flags on pathological samples
    No external compressors = low noise level
    Automatic orifice cleaning
    Printer and serial output as standard
    Easy user interface
    Low reagent consumption, only two reagents
    Self-test program
    Service free closed sampling valve
    Dimensions: H=35, W=42, D=46 cm, 22 kg


QBC VET Autoread (IDEXX)
Zdjęcie0538

IDEXX VetAutoread™ Hematology Analyzer
Comprehensive answers in minutes

The IDEXX VetAutoread™ Hematology Analyzer* offers thorough screening, presurgical testing
and general health checkups in-house.
The IDEXX VetAutoread analyzer connects to the IDEXX VetLab® Station, a laboratory
information management system that collects all results into an electronic medical record and
prints them on an integrated report for easy interpretation.

 

 



Siemens Medical Solutions Diagnostics ADVIA 2120i

Advia2120.1

Siemens’ high-volume hematology analyzer, the ADVIA® 2120i System with Autoslide* streamlines workflow by eliminating the majority of manual steps commonly performed to maximize productivity. It delivers the gold-standard in testing methodology for optimum results while offering the simplicity and flexibility you need for easy integration into your lab.



SYSMEX DD-100

OLYMPUS DIGITAL CAMERA
Trade Name     SYSMEX DD-100 WHOLE BLOOD DILUTION SYSTEM
Device Type     Apparatus, Automated Blood Cell Diluting

 

 

 

 

 

 

 

 

 

 



SYSMEX F-500/F-800

OLYMPUS DIGITAL CAMERAMODEL    F500
COUNTS/DILUTION (APERTURE)    1
SAMPLE VOLUME, µL    20
POWER REQUIRED, VAC    117/220/240
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY)    25x 33 x 48 (9.8x 13 x 18)
WEIGHT, kg (lb) (DISPLAY)    15(33)
TECHNIQUE    Volumetric impedance
COINCIDENCE CORRECT (APERTURE)    Yes
COMPUTER INTERFACE    Optional
CALIBRATION    Semiautomatic
DILUTION (APERTURE)    Semiautomatic
QC PROGRAMS (APERTURE)    Control data printouts
APERTURE    
Number (STAINING POSTS)    1
Size(s), mm (APERTURE)    100
CYCLE DURATION, SEC (APERTURE)    13
START-UP TIME, min (APERTURE)    3
TESTING PACE    80
WARNING SIGNALS (REVOLUTIONS)    Visual14 status OLYMPUS DIGITAL CAMERAmessages
MODIFIABLE THRESHOLD (APERTURE)    Yes
VISUAL OUTPUT (APERTURE)    LED, internal roll printer
TESTS (APERTURE)    WBC, RBC, Hgb, Hct, MCV
OTHER ATTRIBUTES (Interference compensation)    Nonmercury volumetric manometer; patient limits program; auto recount mode; optional auto- diluter.
MARKETING REGION (Interference compensation)    Worldwide
Full Automation    No



SYSMEX K-800/K-1000

OLYMPUS DIGITAL CAMERAOLYMPUS DIGITAL CAMERA

The Sysmex K-1000 a new class of automated hematology analyzer is distinguished by its space-saving design operational simplicity and small sample size requirements. The advanced technology and superior accuracy culminate to make the K-1000 a forerunner in diagnostic hematology analyzer. Within seconds the K-1000 not only analyzes 8 CBC parameters but also generates 10 additional analytical parameters plus WBC RBC and PLT histograms. In addition to its superior diagnostic technology comprehensive monitoring functions a data flagging system and a quality control program are all incorporated in the K-1000 to assure accuracy precision and reliability. Operating the K-1000 with confidence is easy because a variety of messages are displayed on the liquid crystal display and printed by the built-in printer. Furthermore the excellent cost-effectiveness of the K-1000 is an indispensable feature for efficient hematology testing.



SYSMEX K-4500

Zdjęcie0111OLYMPUS DIGITAL CAMERA
K-4500 – 3 diff hematology analyzer

Specification
Manufactures:     Sysmex
Method:    Volume impedance
Parameters:    WBC, W-SCR, W-MCR, W-LCR, W-SCC, W-MCC, W-LCC, RBC, Hgb, Hct, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, P-LCR + 3 histograms WBC, RBC and PLT
Sample:    100 l
Throughput:     80 samples/hour

Hematology analyzer K-4500 is designed for analytical laboratories in hospitals and clinics and also for analytical laboratories working independently. 



SYSMEX KX-21
Sysmex KX21_13845.1

KX-21N – 3 diff hematology analyzer

Specification
Manufactures:     Sysmex
Method:    Volume impedance
Parameters:    WBC, W-SCR, W-MCR, W-LCR, W-SCC, W-MCC, W-LCC, RBC, Hgb, Hct, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, P-LCR + 3 histograms WBC, RBC and PLT
Sample:    50 l
Throughput:     60 samples/hour

Hematology analyzer KX-21N is designed for analytical laboratories in hospitals and clinics and also for analytical laboratories working independently. 

 

 

 



SYSMEX KX-21N

sysmekx21NKX-21N – 3 diff hematology analyzer

Specification
Manufactures:     Sysmex
Method:    Volume impedance
Parameters:    WBC, W-SCR, W-MCR, W-LCR, W-SCC, W-MCC, W-LCC, RBC, Hgb, Hct, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, P-LCR + 3 histograms WBC, RBC and PLT
Sample:    50 l
Throughput:     60 samples/hour

Hematology analyzer KX-21N is designed for analytical laboratories in hospitals and clinics and also for analytical laboratories working independently.

 

 

 

 



SYSMEX Poch 100i

sysmex-poch100The pocH-100i hematology analyzer, designed for laboratories testing up to 25 samples per day, has the smallest footprint of any hematology analyzer on the market. Requiring only 15 µL of EDTA whole blood for reporting 17 clinical parameters with a 3-part WBC Differential, it includes an Absolute Neutrophil Count (ANC). Quality processes are addressed with the pocH-100i closed tube sampling and simple reagent system. Six on-board QC files support assurance of instrument performance. The intuitive push button menu simplifies the operation of this analyzer.

 

 

 



SYSMEX XS 800i
Sysmex xs- 800i.1

The Sysmex XS800i supported by Sysmex Corporation is routinely available from Diamond Diagnostics in refurbished condition. All instruments refurbished by Diamond, including the Sysmex XS800i, are disassembled down to-the-frame then thoroughly cleaned, polished and eventually refinished with a durable 3 part industrial paint that matches the instrument’s original color and sheen. During re-assembly components are validated, repaired or replaced as needed followed by full diagnostics, calibration and running controls as a final step. Afterward the instruments are inspected and prepared for international transit. Should you wish to receive more information on the Sysmex XS800i Hematology Analyzer such as pricing, detailed specifications and availability go to Analyzer Search.
Sysmex XS800i
Manufacturer:           Sysmex Corporation
Type           Hematology Analyzer
Parameters:           21: 5-pt Differential       
Throughput:           50 samples/hour
Method:           Volume Impedence
Open system:           Open
W x D x H:           13X17X16 inches / 33X43X41 cm
Weight:           53 lbs / 24 kilos

 



SYSMEX XS 1000i/ SYSMEX XS 1000i AL

Sysmex XS1000i_62669.2Sysmex XS-1000i Automated Hematology Analyzer

Fluorescent flow cytometry and advanced cell counting in a space-saving footprint makes the Sysmex® XS-Series Automated Hematology Analyzer an excellent choice for laboratories that have smaller sample volumes.  Available with and without an auto sampler, the XS-1000i offers 21 testing parameters and closed tube sampling to assure operator safety. It requires less than four feet of counter space and uses only 20 µL of sample.

Proven Technology
Leading Edge Hematology Diagnostics
Effective diagnostic capabilities utilizing fluorescent flow cytometry

    CBC with 5-part Differential (NEUT + LYMPH + MONO + EO + BASO)
    Standardization across Sysmex platforms
    Proven reliability as a member of the X-Series of products

Streamlined Workflow
True walk-away analytical process with closed tube auto sampling

    Simplicity in operation for streamlined workflow
    Push button, walk-away daily maintenance
    Standardization with other Sysmex solutions for multi-hospital sites

Easy to Use
Intuitive software menus

    Barcoded reagent management
    Comprehensive quality control information
    On-board help key for rapid troubleshooting



SYSMEX XT 1800
Sysmex XT1800i_21015.1

Designed to be reliable and efficient, the Sysmex XT-1800i offers medium volume laboratories an automated hematology system that can truly meet and exceed their expectations.  The XT-1800i provides CBC and differential analysis using the same technologies as the other analyzers in the Sysmex XT-Series and XE-Series lines.  Body fluid samples, including CSF, serous fluid and synovial fluid, are analyzed for RBC and WBC counts.  A 6-part WBC Differential, including enumerated immature granulocytes (IG% and #), is optional for laboratories who need to reduce smear reviews.  The XT-1800i streamlines your workflow by providing testing for up to 80 samples per hour, enabling rapid turnaround time.

 

 

 



SYSMEX XT 2000

Sysmex XT 2000_11015.1The Sysmex XT-2000i offers medium volume laboratories an affordable, reliable automated system to meet their needs for efficient hematology testing.  The analyzer has a second fluorescent platelet method, PLT-O, on-board to help resolve platelet flags and minimize manual counts.  Reticulocytes are fully automatic and require no pretreatments or testing delays.  Body fluid samples, including CSF, serous fluid and synovial fluid, are analyzed for RBC and WBC counts.  The XT-2000i streamlines your workflow by providing testing for up to 80 samples per hour, enabling rapid turnaround time of results.  

The XT-2000i offers the options of a 6-part WBC differential, including enumerated immature granulocytes (IG% and #) and RET-He reticulocyte hemoglobin concentrations. 

 

 

 



SYSMEX XE 2100

Zdjęcie0124Sysmex XE-2100™ Automated Hematology System

 The XE-2100 Automated Hematology System is an easy to use, high volume analyzer with a history of reliability and productivity that provides operational efficiency for the hematology laboratory. Unique fluorescent flow cytometry and hydrodynamic focusing technologies enable the XE-2100 to minimize review rates and produce accurate results even when interferences are present.

Designed to be scalable, reliable and efficient, the Sysmex XE-2100 offers laboratories an automated hematology system that can truly meet and exceed their expectations.  The XE-2100 streamlines your workflow by providing testing for up to 150 samples/hour, enabling rapid turnaround time.

 



SYSMEX XE 5000

Zdjęcie0107The Sysmex XE-5000 Automated Hematology System utilizes the power of fluorescent flow cytometry and hydrodynamic focusing technologies.  Using a unique and advanced diode laser bench, Sysmex fluorescent flow cytometry provides the sensitivity needed for measuring and differentiating cell types in whole blood and body fluid samples.  Fluorescent technology and hydrodynamic focusing enable the XE-5000 to consistently differentiate normal WBC, RBC and PLT populations from abnormal populations, thereby decreasing the number of manual interventions.  The XE-5000 technology provides clinically relevant and reportable parameters.

    Fluorescent NRBC count with excellent sensitivity and specificity to lower review rates
        Provides improved low end sensitivity
        Enables rapid reporting
        Provides efficient automated correction of WBC and differential results
     Immature granulocyte count (IG% and #) offers reportable, quantitative results for metamyelocytes, myelocytes and promyelocytes
        Reduce false positive and false negative rates
        Obtain result consistency by reducing tech-to-tech variation in reporting manual differentials
        Improve turnaround time with fewer manual differentials
    Platelet counts by a fluorescent optical method and by traditional impedance technology to improve accuracy of very low and very high PLT counts
        Obtain accurate counts when interferences are present
        Offers automated judgment for reporting PLT-O or PLT-I through instrument settings
    Retic:  Fluorescent reticulocyte count to reduce manual confirmation methods and their inherent errors
        Eliminate common interferences to avoid manual counts
    RET-He:  Reticulocyte Hemoglobin content measures the incorporation of iron into the red cell to assist the physician with anemia evaluation and management (e.g., functional iron deficiency anemia)
        Provides rapid and direct analysis of an earlier stage of RBC development
        Is an established parameter used in KDOQI (Kidney Disease Outcome Quality Initiative) guidelines for assessing the initial iron status of patients
        Supports effective monitoring of costly drug protocols for cell stimulation
    IPF:  Immature platelet fraction to help the physician monitor thrombopoietic activity of the bone marrow
        Ensures accuracy and sensitivity in measurement of immature platelets
        Offers delineation of abnormal platelet populations seen by physicians in disease states such as AITP (autoimmune thrombocytopenic purpura) or TTP (thrombotic thrombocytopenic purpura)
        Enables rapid reporting of results for prompt clinical information
    HPC:  Quantitative Hematopoietic Progenitor Cell count as a screen that can be used by the physicians to determine the presence of hematopoietic progenitor cells in peripheral blood and cord blood samples
        Offers quality information to better assist physicians with patient treatment protocols
        Allows rapid analysis versus conventional methods for prompt determination of optimal stem cell harvest time
        Reduces costs as the system does not require additional reagents, sample volume or specific technical expertise
    Body Fluids:  Excellent low end sensitivity with seven parameters, including a 2-part Differential
        Provides expanded sensitivity and linearity:  WBC and RBC counts reportable to three decimal places
        Eliminates the need for manual counts by providing a 2-part Differential
        Performs an automated background check prior to analyzing samples



SYSMEX SF-3000

OLYMPUS DIGITAL CAMERASF-3000 – 5 diff Hematology Analyzer

Specification
Manufactures:      Sysmex
Method:       Absorbance cytochemistry and Volume (AcV) technology
Parameters:     23 parameters – WBC, NEUT%, LYMPH%, MONO%, EO%, BASO%, NEUT#, LYMPH#, MONO#, EO#, BASO#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, P-LCR
Sample Volume:  Sampler Mode: Approx. 270 µL
Closed Mode: Approx. 270 µL
Manual Mode: Approx. 170 µL
Capillary Mode: Over 40 µL
Throughput:        80 samples/hour
Memory:        Cell size distribution data (w/ graphs): for 1,000 samples
Scattergrams: for 1,000 samples
    Order information: for 50 samples
    QC files: for 13 QC files

The Sysmex SF-3000 is a technically advanced, computerized, fully automated hematology analyzer with many features, designed for in vitro diagnostic use in clinical laboratories. The SF-3000 provides accurate screening for patients whose hematological abnormalities indicate the need for further testing.